INTERFACING
LOCSYS, Inc.
ROVER II & DATA MANAGER
TO
ESP520DX
DATA RADIO
| This application note provides the basic cable wiring information for connecting a SEA ESP520DX mobile data radio (with data terminal interface) to the LOCSYS Rover II and LOCSYS Data Manager AVL tracking system. Additionally, a procedure is provided for minimally configuring the PC, base and mobile radio wiring so that the system can be tested using the WinAVL LITE Version 1.1 vehicle tracking software. The base unit named DATA MANAGER uses the dial-up networking feature of Microsoft Windows to connect to the PC as you would for an external modem. The information in this application note is believed to be correct at the time of issuance and is provided strictly as a courtesy to SEA customers without warranty. |
![]()
A UNIT OF DATAMARINE INTERNATIONAL INC.
7030 220th St. S.W.
Mountlake Terrace, WA 98043
(425) 771-2182, FAX: (425) 771-2650
AN-4
4-6-99
1. Minimum system requirements:
| 2 | - | SEA 520DX Data Radios. |
|---|---|---|
| 2 | - | Radio to LOCSYS Rover II interface cables. Refer to section 2 for details. |
| 1 | - | LOCSYS Rover II with 1200 baud modem - programmed for use on SEA 520DX radios. See note below. |
| 1 | - | LOCSYS DATA MANAGER and serial cable for
connection to PC comm port. (Data Manager is the same as the Rover II without the GPS option.) |
| 1 | - | PC with 32-bit Windows 95 or NT 4.0 operating system. |
| 1 | - | Software: WinAVL LITE Version 1.1 with street map of operating area (By state). |
| NOTE: | Rover systems are pre-configured by LOCSYS internally for the radio system they are being used on. When ordering the AVL system from LOCSYS, specify that the system will be used with SEA520DX data radios. |
2. Radio to Rover II wiring diagram:
| NOTE: | Base unit (DATA MANAGER) wiring is the same as the mobile for the DB-25 radio connection. |
| Radio Side DB-25 Male |
Rover II side 24 Pin Mini-Universal locking connector (supplied with Rover II) |
|||
|---|---|---|---|---|
| 5 | ------ | PTT | ------ | 11 |
| 6 | ------ | CTS | ------ | 20 |
| 10 | ------ | RX | ------ | 15 |
| 11 | ------ | GND | ------ | 17 |
| 12 | ------ | TX | ------ | 14 |
| 13 | ------ | +13VSW | ------ | 13 |
| 20 | ------ | DSR | ------ | 9 |
3. ESP 520DX Programming:
Jumper JU105 on the ESP520DX computer (PCB-0505-02) board must NOT be installed for 1200 bps (Bell 202 or MSK) data operation when trunking data transmission is also desired. A regular mode (not available on test modes) is programmed for 1200 bps data operation as follows:
| Required Configuration Programming: | |
|---|---|
| Data Type: | MSK |
Required Mode Programming: |
|
| Type: | Trunked or Conventional |
| Area: | Site Area bit |
| Data Enable: | Voice & Data or Data Only |
| Home: | Desired home channel of site |
| Busy Channel Lockout: | Y |
| Repeater Channel: | Channel number in Home position |
| Priority #2 ID: | Data DTL ID |
When the radio is on a mode programmed for Voice & Data, the Local Mic may key for voice operation and the MDT may key for data operation. When the radio is on a mode programmed for Data Only, only the MDT may key it. Please note if selecting Voice & Data operation, a TX and an RX ID (that do not match the Data ID) are also required for the mode programming.
4. SEA Repeater system programming:
Program the site repeater(s) according to the programming manual with the correct Channel Number, Area Bit and Home Channel. Test the repeaters with two mobiles in VOICE mode to insure the system is functioning properly before using DATA mode on the mobiles.
5. Mobile Station Configuration:

6. Base Station Configuration:

7. Minimum required Base Station Configuration Procedure:
LOCSYS, INC.
A Location Systems Company
904 S. Park Ave.
Tucson, AZ 85719
PHONE: (520) 882-8730
FAX: (520) 624-2727